FixVault

Installation Procedure

  1. If the fuel level sending unit is being replaced, install the fuel level sending unit into the new fuel pump. Refer to Fuel Level Sensor Replacement - Secondary .
    Fig 1: View Of Fuel Tank Module
    GM1226439Courtesy of GENERAL MOTORS CORP.
  2. Connect the suction port (1).
    Fig 2: View Of Suction Port
    GM1346873Courtesy of GENERAL MOTORS CORP.
  3. Insert the new secondary fuel pump module with the level sender and new fuel pump-to-tank seal. Ensure the orientation tabs are aligned.
  4. Use the SA9156E  to install the fuel pump lock ring. See Special Tools .
  5. Connect the EVAP line quick connect.
  6. Install the fuel tank. Refer to Fuel Tank Replacement .