FixVault

Circuit/System Testing

Hood Ajar Switch Malfunction

  1. Ignition OFF, disconnect the harness connector at the hood ajar switch.
  2. Ignition OFF, test for less than 1.0 ohm of resistance between the ground circuit terminal B and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition ON, verify the scan tool Hood Ajar Switch Parameter is Open.
    • If not the specified value, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the BCM.
  4. Install a 3 A fused jumper wire between the signal circuit terminal A and ground. Verify the scan tool Hood Ajar Switch Parameter is Closed.
    • If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.
  5. If all circuits test normal, replace the hood ajar switch.