FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the RCDLR.
  2. Ignition ON, test for greater than 1 ohm between the keyless entry serial data circuit and ground.
    • If less than 1 ohm, test the keyless entry serial data circuit for a short to ground. If the circuit tests normal, replace the BCM.
  3. If all circuits test normal, test or replace the RCDLR.