FixVault

Fastener Tightening Specifications

WARNING: This page is about a different car, the 2005 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Fastener Tightening Specifications

Application Specification
Metric English
Battery Terminal Bolt 17 N.m 13 lb. ft.
Crossover Pipe Bolts-L66 22 N.m 16 lb. ft.
ECT Sensor 18 N.m 13 lb. ft.
Exhaust Manifold Heat Shield Bolts - L61 25 N.m 18 lb. ft.
Thermostat Housing Bolts - L66 12 N.m 106 lb. in.
Thermostat Housing Cover-to-Thermostat Housing Bolts - L61 10 N.m 89 lb. in.
Thermostat Housing-to-Block Bolts - L61 10 N.m 89 lb. in.
Thermostat Pipe Bracket-to-Cylinder Head Bolt - L61 8 N.m 71 lb. in.
Water Pump Access Bolts-to-Front Cover - L61 10 N.m 89 lb. in.
Water Pump Bolts - L61 25 N.m 18 lb. ft.
Water Pump Bolts - L66 12 N.m 106 lb. in.
Water Pump Sprocket-to-Water Pump Bolts - L61 10 N.m 89 lb. in.
Wheel Nuts 125 N.m 92 lb. ft.
Wiring Harness Ground Terminal Nut 12 N.m 106 lb. in.