FixVault

Installation Procedure

    NOTE: Refer to Fastener Notice .
  1. Install the crankshaft position sensor.

    Tighten:  Tighten the bolt to 4.5 N.m (40 lb in).

    • Install the wiring harness plug into the bracket.
    • Install the wiring harness plug.
  2. Install the starter. Refer to Starter Motor Replacement .