System Testing
- Remove the fuel pump module access cover.
- Ignition OFF, install the J 41413-200 (J 41413-100) and the GE-41415-50 . Test for a fuel leak while the system is under pressure referring to the J 41413-210 Operation Manual.
- Using the J 41413-200
(J 41413-100) and the J 41413-210 Operation Manual, introduce smoke into the evaporative emission (EVAP) system. Inspect for leaks in any of the following locations:
- The fuel tank, the fill limiter vent valve, the pressure relief valve, and the grade vent valve
- The fuel pump module housing, the fuel pump module seal, the fuel pipe, and the EVAP pipes
- The fuel tank pressure (FTP) sensor seal
- The fuel fill pipe and hose
IMPORTANT:
If the floating indicator registers any flow after stabilizing, a leak is evident.