Assembly Procedure
WARNING:
In order to reduce the risk of fire and personal injury that may result from a fuel leak, always replace the fuel sender gasket when reinstalling the fuel sender assembly.
NOTE:
- Some lock rings were manufactured with "DO NOT REUSE" stamped into them. These lock rings may be reused if they are not damaged or warped.
- Inspect the lock ring for damage due to improper removal or installation procedures. If damage is found, install a NEW fuel pump module.
- Inspect the lock ring for flatness as best as possible. If the lock ring is warped, replace the fuel pump module.
- Install the fuel tank shield and retainers.
- Clean any contamination from the male pipe ends of the fuel pump module.
- Place a NEW fuel tank module seal onto the fuel tank.
- Insert the fuel pump module into the fuel tank allowing the sensor arm and float to clear the module opening.
- Lower the module down into the fuel tank until the fuel tank vent pipe quick connect fitting can be connected.
- Connect the fuel tank vent pipe quick connect fitting (1) at the module cover. Refer to Plastic Collar Quick Connect Fitting Service .
- Press the fuel tank module downward.
- Install the J 45722 to the fuel pump module lock ring.
- Using the J 45722 and a long breaker-bar, rotate the lock ring in a clockwise direction in order the lock the lock ring.
- Remove the J 45722 from the fuel pump module lock ring.
- Install the EVAP canister and the EVAP canister vent solenoid as an assembly. Slide the EVAP canister vent solenoid onto the fuel tank bracket until the retaining tab is engaged.
- Install the EVAP canister bolt.
Tighten: Tighten the bolt to 3.5 N.m (31 lb in).
- Install the fuel tank fuel pump module wiring harness.
- Connect the fuel tank fuel pump module wiring harness electrical connector (1) to the EVAP canister vent solenoid, and the fuel pressure sensor connector to the fuel pressure sensor, if equipped.
- Connect the fuel tank fuel pump module wiring harness electrical connectors (1, 2) to the fuel pressure sensor if equipped, and the module.
- Install the fuel tank vent pipe to the fuel tank.
- Connect the fuel feed pipe to the fuel pump module assembly. Refer to Plastic Collar Quick Connect Fitting Service
- Connect the fuel tank vent pipe quick connect fitting (1) to the EVAP canister. Refer to Plastic Collar Quick Connect Fitting Service .
- Connect the fuel tank vent pipe quick connect fittings (3, 4) to the module. Refer to Plastic Collar Quick Connect Fitting Service .
- Install the fuel feed pipe to the retaining features (2, 4) built into the fuel tank.
- Install the fuel tank vent pipe to the retaining features (1) built into the fuel tank.
- Install the fuel tank fuel pump module wiring harness to the retaining features (5) built into the fuel tank.
- Install the EVAP emission canister purge pipe to the retaining features (3) built into the fuel tank.
NOTE:
Ensure that the lock ring is installed with the correct side facing upward. A correctly installed lock ring will only turn in a clockwise direction.
CAUTION:
Refer to Fastener Caution
.