Inspection Procedure

  1. INSPECT COMBINATION METER ASSY 
    1. Disconnect the C6 connector.
    2. Measure the resistance according to the value(s) in the table shown in COMBINATION METER TERMINAL RESISTANCE .

      Standard: 

      COMBINATION METER TERMINAL RESISTANCE

      Tester connection Condition Specified condition
      C6-1 - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table shown in COMBINATION METER TERMINAL VOLTAGE .

      Standard: 

      COMBINATION METER TERMINAL VOLTAGE

      Tester connection Condition Specified condition
      C6-3 - Body ground Always 10 to 14 V
      C6-4 - Body ground Ignition switch ON 10 to 14 V
      Fig 1: Identifying Combination Meter Connector
      G03065173Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR CONNECTOR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE COMBINATION METER ASSY (See  ON-VEHICLE INSPECTION  )