FixVault

Mode 6 - 2005 Scion: XA

TID $04: HO2S HEATER

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 1) Malfunction threshold for HO2S heater
1 $02 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction threshold for HO2S heater
TID $08: THERMOSTAT

TLT CID Unit Conversion Description Test Value Description of Test Limit
0 $01 Multiply by 0.625 and subtract 40°C ECT sensor output when estimated ECT has reached to malfunction criterion malfunction criterion for thermostat
O2S TEST RESULTS

TID Unit Conversion Description of Test Value Malfunction Criterion
$07 Multiply by 0.005 (V) Minimum sensor voltage Less than 0.4 V
$08 Multiply by 0.005 (V) Minimum sensor voltage More than 0.55 V
$81 Multiply by 0.001 (Second) Continuous time that HO2S voltage is outside operating range Varies with operating conditions
O2S TEST RESULT (MODE 05 DATA)

TID Unit Conversion Description of Test Value Malfunction Criterion
$03 Multiply by 0.005 (V) This value is used to calculate TID $31 and $32 -
$04 Multiply by 0.005 (V) This value is used to calculate TID $31 and $32 -
$31 Multiply by 0.04 (Second) Lean to Rich switch time Less than 0.9 seconds
$32 Multiply by 0.04 (Second) Rich to Lean switch time Less than 0.9 seconds
$38 Multiply by 0.04 (Second) Average time per one cycle of HO2S voltage Varies with operating conditions
O2S TEST RESULTS

TID Unit Conversion Description of Test Value Malfunction Criterion
$07 Multiply by 0.005 (V) Minimum sensor voltage 0.4 V (or less)
$08 Multiply by 0.005 (V) Minimum sensor voltage 0.5 V (or more)
$31 Multiply by 0.04 (Second) Lean to Rich switch time (This test value is not use malfunction determination) -
$32 Multiply by 0.04 (Second) Rich to Lean switch time (This test value is not use malfunction determination) -
$37 Multiply by 0.04 (Second) Rich to Lean switch time during fuel-cut (This test value is not use malfunction determination) -
$39 Multiply by 0.04 (Second) Time that HO2S voltage drops from 0.35 V to 0.2 V during fuel-cut (This test value is not use malfunction determination) -
$81 Multiply by 0.39 (%) Percentage in monitor time that sensor voltage is less than 0.05 V 60% (or more)
$84 Multiply by 0.39 (%) Percentage in monitor time that sensor voltage is more than 0.7 V 20% (or less)
$85 Multiply by 0.26 (Second) Duration that sensor voltage is 0.45 V or higher 20 seconds (or less)
$87 Multiply by 0.39 (%) Percentage in monitor time that sensor voltage is more than 0.45 V 40% (or less)
TID $01: CATALYST TEST RESULT

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.0078 [no dimension]
Catalyst deterioration level bank 1:
Determined by waveforms of HO2S sensor 1 and sensor 2 Malfunction criteria for catalyst deterioration
TID $02: EVAP - LEV II VACUUM MONITOR

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.0183 [mmHg] Test value of EVAP VSV stuck close:
Determined by fuel tank pressure change during vacuum introduction
Malfunction criteria for EVAP VSV stuck close
0 $02 Multiply by 0.0655 [seconds] Test value of EVAP VSV stuck open:
Determined by duration that fuel tank pressure is higher than criteria
Malfunction criteria for EVAP VSV stuck open
0 $03 Multiply by 0.0655 [seconds] Test value of canister closed valve (CCV):
Determined by duration that fuel tank pressure is lower than criteria
Malfunction criteria for CCV
0 $04 Multiply by 0.0458 [mmHg] Test value of 0.04 inch leak:
Determined by fuel tank pressure change
Malfunction criteria for 0.04 inch leak
0 $05 Multiply by 0.0458 subtract 2.93 [mmHg] Test value of 0.02 inch leak:
Determined by fuel tank pressure change
Malfunction criteria for 0.02 inch leak