MONITOR STRATEGY

Related DTCs P0133: Heated Oxygen (HO2) sensor (bank 1 sensor 1) responsibility
P0133: HO2 sensor (bank 1 sensor 1) frequency at idle
P0133: HO2 sensor (bank 1 sensor 1) frequency at driving
Required Sensors/Components (Main) HO2 sensor (sensor 1)
Required Sensors/Components (Related) None
Frequency of Operation Continuous
Duration 60 seconds
MIL Operation 2 driving cycles
Sequence of Operation None