Freeze Frame Data
- FREEZE FRAME DATA
HINT:
- When a DTC is detected or the ABS operates, the skid control ECU stores the current vehicle (sensor) state as freeze frame data.
- The skid control ECU stores the number of times (maximum: 31) the ignition switch has been turned from OFF to ON since the last time the ABS was activated. However, if the vehicle is stopped, the vehicle is driven at 7 km/h (4.3 mph) or less, or a DTC is detected, the ECU will not count the next time the ignition switch is turned from OFF to ON.
- Freeze frame data at the time the ABS operates: The skid control ECU stores data or updates stored data when the ABS operates. This data is erased when the ECU stores data at the time a DTC is detected.
- Freeze frame data at the time a DTC is detected: When the skid control ECU stores data at the time a DTC is detected, the data will not be updated until the data is cleared.
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON.
- From the display on the tester, select FREEZE FRAME DATA.MEASUREMENT ITEM REFERENCE VALUE
Intelligent tester display Measurement item Reference value VEHICLE SPD Vehicle speed Speed indication on meter STOP LIGHT SW Stop light switch signal Stop light switch ON: ON
Stop light switch OFF: OFF# IG ON Number of ignition switch OFF to ON operations after memorizing freeze frame data 0 to 31 MAS CYL PRESS Master cylinder pressure sensor reading Brake pedal released: 0.3 to 0.9 V
Brake pedal depressed: 0.8 to 4.5 VMASS PRESS GRADE Master cylinder pressure sensor change Min.: -30 MPa/s
Max.: 200 MPa/sSYSTEM Information about system / mode status No system activated: NO SYS
ABS operating: ABS
Fail-safe mode activated: FAIL SFYAW RATE Yaw rate sensor reading -100 to 100 STEERING ANG Steering angle sensor reading Left turn: Increase
Right turn: DropTHROTTLE Throttle position sensor reading Release accelerator pedal: Approx. 0 deg.
Depress accelerator pedal: Approx. 90 deg.G (RIGHT & LEFT) Forward and rearward gravitational force (G) Min.: -1.869
Max.: 1.869G (BACK & FORTH) Forward and rearward gravitational force (G) Min.: -1.869
Max.: 1.869VSC (TRAC) OFF SW VSC OFF switch signal Traction OFF switch ON: OFF, OFF: ON SHIFT POSITION Shift lever position FAIL
P*, N*
R
D
2
LHINT:
*: The A/C switch is OFF and all accessory switches are OFF.