Wireless Door Lock Control System: Registration
HINT:
- If replacing the door control transmitter or the door control receiver, register its recognition code to the integration relay.
- Add mode is used to register new recognition codes while still retaining codes already registered. This mode is used when a new transmitter is added. If the number of registered codes exceeds 4, the previously registered codes will be erased in order, starting from the code that was registered first.
- Rewrite mode is used to erase all the previously registered recognition codes in order to register all new recognition codes. This mode is used when the transmitter or the door control receiver is replaced.
- Confirmation mode is used to confirm how many recognition codes have already been registered before another recognition code is registered.
- Prohibition mode is used to erase all the registered codes and disable the wireless door lock function. This mode is used when the transmitter is lost.
- All of the following registration procedures must be performed in order.
- REGISTER RECOGNITION CODE (SWITCH OPERATION)
- The following conditions should be met:
- No key in ignition key cylinder.
- Only driver side door is opened.
- Insert the key into the ignition key cylinder and pull it out (Procedure "A").
- Insert the key into the ignition key cylinder, and then pull it out within 5 seconds after Procedure "A" (Procedure "B").
- Close and open the driver side door twice.
- Insert the key into the ignition key cylinder, and then pull it out within 40 seconds after Procedure "B" (Procedure "C").
- Close and open the driver side door twice.
- Insert the key into the ignition key cylinder and close all doors within 40 seconds after Procedure "C" (Procedure "D").
- Turn the ignition switch from LOCK to ON and back to LOCK at approximately 1 second intervals according to the number of times shown in the table below.
Number of ON-LOCK operations of ignition switch:
IGNITION SWITCH ON-LOCK OPERATIONS REFERENCEMode Selection Ignition Switch ON-LOCK Operation Ignition Key Status Add mode Once - Ignition switch status "ON"
- Ignition switch status "LOCK"
T1: Approximately 1 secondRewrite Mode Twice - Ignition switch status "ON"
- Ignition switch status "LOCK"
T1: Approximately 1 secondConfirmation Mode 3 times - Ignition switch status "ON"
- Ignition switch status "LOCK"
T1: Approximately 1 secondProhibition Mode 5 times - Ignition switch status "ON"
- Ignition switch status "LOCK"
T1: Approximately 1 secondHINT:
If the number of the ON-LOCK operations of the ignition switch is 0,4 or 6 or more, there will be no response (power door LOCK-UNLOCK operation) to show which mode has been selected.
- Remove the key from the ignition key cylinder within 40 seconds after Procedure "D" (Procedure "E").
- The integration relay automatically performs power door LOCK-UNLOCK operations to indicate which mode has been selected.
Response to selected mode (Power door lock operation):
ON-LOCK OPERATIONS REFERENCE (POWER DOOR LOCK OPERATION)Mode Selection Power Door Lock LOCK-UNLOCK Door Lock Status Add mode Once - Door lock motor status "LOCK"
- Door lock motor status "UNLOCK"
T1: Approximately 1 secondRewrite Mode Twice - Door lock motor status "LOCK"
- Door lock motor status "UNLOCK"
T1: Approximately 1 secondConfirmation Mode The number of registered codes (1 to 5 times) - Door lock motor status "LOCK"
- Door lock motor status "UNLOCK"
- 1st time
- 2nd time
T1: Approximately 1 second
T2: Approximately 2 secondsProhibition Mode 5 times - Door lock motor status "LOCK"
- Door lock motor status "UNLOCK"
T1: Approximately 1 secondHINT:
- In confirmation mode, the LOCK-UNLOCK operation will occur once for each recognition code that has been registered. For example, if 2 recognition codes have been registered, the LOCK-UNLOCK operation will occur twice.
- In confirmation mode, if no recognition codes have been registered, the LOCK-UNLOCK operation will occur 5 times.
Next step
MODE SELECTION CHARTMode Selection Procedure Add Mode Continued in next step. Rewrite Mode Confirmation Mode Registration procedures are completed. Prohibition Mode - Press both the LOCK and UNLOCK switches on the transmitter simultaneously (Procedure "F").
- Press a single switch (LOCK or UNLOCK) within 45 seconds after Procedure "E".
- The integration relay automatically performs power door LOCK-UNLOCK operations to show whether registration has been completed correct or not.
Response to registration completion:
REGISTRATION COMPLETION CHARTPower Door Lock LOCK-UNLOCK Opearation Result Door Lock Status Once Registration of recognition code has been completed. - Door lock motor status "LOCK"
- Door lock motor status "UNLOCK"
T1: Approximately 1 secondTwice Registration of recognition code has failed. - Door lock motor status "LOCK"
- Door lock motor status "UNLOCK"
T1: Approximately 1 secondHINT:
If registration of a recognition code has failed, perform registration procedures again from the beginning.
Next step
NEXT OPERATION PROCEDURENext Operation Procedure When another transmitter needs to registered. Return to procedure "F" within 40 seconds *. When registration procedures are completed. Continued in next step. HINT:
*: All 4 recognition codes can be registered consecutively. - Perform either of the following:
- Open a door.
- Insert key into ignition key cylinder.
- Registration of recognition codes (add mode and rewrite mode) is completed.
HINT:
All 4 recognition codes can be registered consecutively.
- The following conditions should be met: