FixVault

Inspection Procedure

  1. INSPECT FUSE (IG2, ECU-B, AM2, DCC) 
    1. Remove the IG2 fuse from the instrument panel junction block.
    2. Remove the ECU-B, DCC and AM2 fuses from the engine room relay block.
    3. Measure the resistance of the fuses.

      Standard resistance: 

      Below 1 Ω 

    NG: REPLACE FUSE 

    OK: Go to next step 

  2. CHECK WIRE HARNESS (TRANSPONDER KEY ECU ASSEMBLY - BATTERY AND BODY GROUND) 
    1. Disconnect the T8 ECU connector.
    2. Measure the resistance and voltage of the wire harness and connector.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition
      T8-14 (GND) - Body ground Below 1 Ω

      Standard voltage 

      VOLTAGE SPECIFICATION

      Tester Connection Condition Specified Condition
      T8-2 (IG) - Body ground Ignition switch OFF Below 1 V
      Ignition switch ON 10 to 14 V
      T8-1 (+B) - Body ground Always
      Fig 1: Identifying T8 ECU Connector
      G05541333Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS AND CONNECTOR 

    OK: REPLACE TRANSPONDER KEY ECU ASSEMBLY