Ignition Switch: Inspection
- INSPECT IGNITION SWITCH ASSEMBLY
- Check the resistance.
- Measure the resistance between the terminals.
Standard resistance
STANDARD RESISTANCE REFERENCESwitch Condition Tester Connection Specified Condition LOCK - 10 kΩ or higher ACC 2 (AM1) - 3 (ACC) Below 1 Ω ON 2 (AM1) - 3 (ACC)
3 (ACC)-4 (IG1)
7 (AM2) - 6 (IG2)Below 1 Ω START 2 (AM1) - 4 (IG1)
4 (IG1)-1 (ST1)
7 (AM2) - 6 (IG2) - 8
(ST2)Below 1 Ω If the result is not as specified, replace the ignition switch assembly.
- Measure the resistance between the terminals.
- Check the resistance.