Door Control Switch: Inspection
- INSPECT POWER WINDOW REGULATOR MASTER SWITCH (w/Jam Protection Function)
- Inspect door control switch.
- Measure the resistance of the door control switch.
Standard resistance
RESISTANCE REFERENCE
| Tester Connection |
Switch Condition |
Specified Condition |
| 2-4 |
Lock |
Below 1 Ω |
| 2-4 |
OFF (Free) |
10 kΩ or higher |
| 2-14 |
Unlock |
Below 1 Ω |
| 2-14 |
OFF (Free) |
10 kΩ or higher |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- INSPECT POWER WINDOW REGULATOR MASTER SWITCH (w/o Jam Protection Function)
- Inspect door control switch.
- Measure the resistance of the door control switch.
Standard resistance
RESISTANCE REFERENCE
| Tester Connection |
Switch Condition |
Specified Condition |
| 1-2 |
Lock |
Below 1 Ω |
| 1-2 |
OFF (Free) |
10 kΩ or higher |
| 1-5 |
Unlock |
Below 1 Ω |
| 1-5 |
OFF (Free) |
10 kΩ or higher |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- INSPECT DOOR CONTROL SWITCH (w/ Jam Protection Function)
- Inspect door control switch.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
RESISTANCE REFERENCE
| Tester Connection |
Switch Condition |
Specified Condition |
| 2-3 |
Lock |
Below 1 Ω |
| 1-2 |
Unlock |
Below 1 Ω |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- INSPECT DOOR CONTROL SWITCH (w/o Jam Protection Function)
- Inspect door control switch.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
RESISTANCE REFERENCE
| Tester Connection |
Switch Condition |
Specified Condition |
| 3-6 |
Lock |
Below 1 Ω |
| 3-5 |
Unlock |
Below 1 Ω |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002