Inspection Procedure
- CHECK HARNESS AND CONNECTOR (DLC3 - ECM AND BODY GROUND)
- Disconnect the A36 connector from the ECM.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition A36-27 (TC) - C14-13 (TC)
C14-4 (CG) - Body groundAlways Below 1 Ω C14-13 (TC) - Body ground Always 10 kΩ or higher - Reconnect the connector from the ECM.
NG : REPAIR OR REPLACE HARNESS OR CONNECTOR OR EACH ECU
OK : PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE .