FixVault

VSC Off Switch: Inspection

  1. INSPECT VSC OFF SWITCH 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      STANDARD RESISTANCE SPECIFICATIONS

      Tester Connection Switch Condition Specified Condition
      3 - 6 Released 10 kΩ or higher
      3 - 6 Pushed in Below 25 Ω

      If the result is not as specified, replace the VSC off switch.

    2. Check illumination operation.

      Standard resistance 

      STANDARD RESISTANCE SPECIFICATIONS

      Tester Connection Switch Condition Specified Condition
      4 - 5 Battery's positive (+) lead connected to terminal 5 and negative (-) lead to terminal 4 LED illuminates

      If the result is not as specified, replace the VSC off switch.

      Fig 1: Inspecting VSC OFF Switch
      G05389568Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002