Data List / Active Test
WARNING: This page is about a different car, the 2008 Scion xB. However, it is still accessible from the selected car via links, so may be relevant.
- DATA LIST
HINT:
Using an intelligent tester or Techstream to read the DATA LIST allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the DATA LIST information early in troubleshooting is one way to save diagnostic time.
NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.- Connect an intelligent tester or Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester on.
- Enter the following menus.
- Intelligent tester - Select: DIAGNOSIS / OBD/ MOBD / BODY SYSTEM / OCCUPANT DETECT / DATA LIST.
- Techstream - Select: Body Electrical / Occupant Detection / Data List.
- According to the display on tester, read the "DATA LIST" or "Data List".
- Intelligent tester
OCCUPANT DETECT:
DATA LIST - OCCUPANT DETECTTester Display Measurement Item/ Range Normal Condition Specified Condition for Zero Point Calibration Diagnostic Note PASSENGER CLASS Passenger classification / NG, AM50, AF05, CHILD or OFF NG Data is not determined
AM50 Adult is seated and seat is in rear position
AF05 Adult is seated and seat is in front position
CHILD Child is seated OFF VacantOFF - P BUCKLE SW Buckle switch (passenger side) / SET, UNSET or NG SET Passenger side seat belt is fastened
UNSET Passenger side seat belt is unfastened
NG Data is not determinedUNSET - RELATIVE PRESS Pressure sensor output / Min 0, Max 255 0 to 210 (reference value) 0 to 2 - FILTERED PRESS Filtered pressure sensor output / Min 0, Max 255 38 to 240 38 to 75 If value is outside range of Specified Condition for Zero Point Calibration, check whether any objects are placed on seat cushion and that seat cushion is fitted correctly THERMISTOR TEMP Thermistor temperature output/ Min. -40°C (-40°F), Max. 90°C (194°F) 40 to 85°C (-40 to 185°F) 3 to 40°C (36 to 104°F) If value is outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc WEIGHT THRESH Weight threshold/ Min. 0, Max. 255 36 to 67 (reference value) 36 to 67 (reference value) - FILTERED TENSION Filtered belt tension output / Min 0, Max 255 39 to 229 39 to 64 (no load) - EMPTY THRESH Empty threshold value from seat factory / Min. 0, Max.. 255 38 to 75 38 to 75 - ALLOW THRESH Threshold value for adult passenger or not from seat factory / Min 0, Max: 255 43 to 64 (reference value) 43 to 64 (reference value) - RESENT CODES Number of present trouble codes / Min 0, Max. 255 0 0 - #PAST CODES Number of past trouble codes / Min 0, Max 255 0 0 - - Techstream
Occupant Detection:
DATA LIST - OCCUPANT DETECTIONTester Display Measurement Item/ Range Normal Condition Specified Condition for Zero Point Calibration Diagnostic Note Passenger Classification Passenger classification / NG, AM50, AF05, Child or OFF NG Data is not determined
AM50. Adult is seated and seat is in rear position
AF05. Adult is seated and seat is in front position
Child. Child is seated OFF VacantOFF - Passenger Buckle SW Buckle switch (passenger side) / Set, Unset or NG Set Passenger side seat belt is fastened
Unset. Passenger side seat belt is unfastened
NG Data is not determinedUnset - Pressure sensor output Pressure sensor output / Min 0, Max. 255 0 to 210 (reference value) 0 to 2 - Filtered pressure sensor output Filtered pressure sensor output / Min 0, Max. 255 38 to 240 38 to 75 If value is outside range of Specified Condition for Zero Point Calibration, check whether any objects are placed on seat cushion and that seat cushion is fitted correctly Thermistor temperature output Thermistor temperature output/ Min -40°C (-40°F), Max. 90°C (194°F) -40° to 85°C (-40° to 185°F) 3° to 40°C (36° to 104°F) If value is outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc. Weight threshold Weight threshold/ Min 0, Max. 255 36 to 67 (reference value) 36 to 67 (reference value) - Filtered belt tension output Filtered belt tension output / Min 0, Max.: 255 39 to 229 39 to 64 (no load) - Empty threshold value from seat factory Empty threshold value from seat factory / Min 0, Max 255 38 to 75 38 to 75 - Allow threshold Threshold value for adult passenger or not from seat factory / Min 0, Max. 255 43 to 64 (reference value) 43 to 64 (reference value) - Number of Present DTC Number of present trouble codes / Min. 0, Max 255 0 0 - Number of Past DTC Number of past trouble codes / Min 0, Max. 255 0 0 -
- Intelligent tester