FixVault

Monitor Strategy

MONITOR STRATEGY

Related DTCs P0420: Catalyst Deterioration
Required Sensors/Components (Main) Air fuel ratio sensor
Heated oxygen sensor
Required Sensors/Components (Related) Intake air temperature sensor
Mass air flow meter
Crankshaft position sensor
Engine coolant temperature sensor
Frequency of Operation Once per driving cycle
Duration About 30 seconds
MIL Operation 2 driving cycles
Sequence of Operation None