Load Test
Hook up test equipment. See Figure. Apply specified load to starter. See STARTER LOAD SPECIFICATION table. On automatic transmission, voltage should drop to no lower than 8 volts. Starter should rotate at 880 RPM with current draw less than 370 amps. For manual transmission vehicles, see STARTER OUTPUT SPECIFICATION table.
STARTER LOAD SPECIFICATION
| Application | (1) Volts | ||
|---|---|---|---|
| Legacy | 7 (10) | ||
| Loyale | 4.7 (6.4) | ||
| XT & XT6 | 6.3 (8.5) | ||
|
|||
STARTER OUTPUT SPECIFICATION
| Application | Minimum RPM | Maximum Amps |
|---|---|---|
| Legacy | 900 | 280 |
| Loyale | 1180 | 230 |
| XT & XT6 | 980 | 280 |