Power Mirror Motor Test: Legacy
Remove door panel. Unplug mirror motor 6-pin harness connector. Using 12-volt power supply and 2 jumper wires, apply voltage to specified terminal and ground other specified terminal as per table. See POWER MIRROR MOTOR TEST . SeeFig 1.
POWER MIRROR MOTOR TEST
| Function | Battery Terminal | Ground Terminal |
|---|---|---|
| Up | 1 | 3 |
| Down | 3 | 1 |
| Right | 3 | 2 |
| Left | 2 | 3 |
| SVX | ||
| Up | 4 | 2 |
| Down | 2 | 4 |
| Right | 2 | 1 |
| Left | 1 | 2 |