FixVault

Function Test

  1. Turn off engine. Disconnect electrical connector from vacuum pump and valve assembly. Apply battery positive lead to terminal No. 2, and negative lead to terminals No. 1 and 4. SeeFig 1 . Ground terminal No. 3. If throttle does not fully open within 3 seconds, replace vacuum pump and valve assembly.
  2. If throttle fully opens within 3 seconds, disconnect battery lead from terminal No. 2. If throttle does not fully close within 3 seconds, check actuator. See ACTUATOR TEST  under TESTING. If actuator is okay, replace vacuum pump and valve assembly.
Fig 1: Identifying Vacuum Pump & Valve Assembly Connector Terminals
G93B02311Courtesy of SUBARU OF AMERICA, INC.