FixVault

Power Mirror Motor

Remove door panel. Disconnect mirror motor connector. Using 12-volt power supply and 2 jumper wires, apply voltage to specified terminal and ground specified terminal. See POWER MIRROR MOTOR TEST  . SeeFig 1 , Fig 2 or Fig 3 .

POWER MIRROR MOTOR TEST

Movement Terminal No. (+) Terminal No. (-)
Impreza
Up 1 3
Down 3 1
Left 1 2
Right 2 1
Legacy
Up 1 3
Down 3 1
Left 2 3
Right 3 2
SVX
Up 4 2
Down 2 4
Left 1 2
Right 2 1
Fig 1: Mirror Motor Connector Terminal ID (Impreza)
G93F84405Courtesy of SUBARU OF AMERICA, INC.
Fig 2: Mirror Motor Connector Terminal ID (Legacy)
G92G01696Courtesy of SUBARU OF AMERICA, INC.
Fig 3: Mirror Motor Connector Terminal ID (SVX)
G93I02319Courtesy of SUBARU OF AMERICA, INC.