Power Mirror Motor
Remove door panel. Disconnect mirror motor connector. Using 12-volt power supply and 2 jumper wires, apply voltage to specified terminal and ground specified terminal. See POWER MIRROR MOTOR TEST . SeeFig 1 , Fig 2 or Fig 3 .
POWER MIRROR MOTOR TEST
| Movement | Terminal No. (+) | Terminal No. (-) | |
|---|---|---|---|
| Impreza | |||
| Up | 1 | 3 | |
| Down | 3 | 1 | |
| Left | 1 | 2 | |
| Right | 2 | 1 | |
| Legacy | |||
| Up | 1 | 3 | |
| Down | 3 | 1 | |
| Left | 2 | 3 | |
| Right | 3 | 2 | |
| SVX | |||
| Up | 4 | 2 | |
| Down | 2 | 4 | |
| Left | 1 | 2 | |
| Right | 2 | 1 | |