FixVault

Mass Airflow (MAF) Sensor

Remove rubber cover from electrical connector on airflow sensor. Backprobe between terminals to make voltage measurements. Unplug connector to make resistance measurements. See MAF SENSOR TEST SPECIFICATIONS table. If readings are not as specified, check wiring. See WIRING DIAGRAMS article. If wiring is okay, replace airflow sensor.

MAF SENSOR TEST SPECIFICATIONS

Ign. Switch Wire Colors Readings
Key Off Black & Ground 0-10 Ohms
Key On Red & Ground 10 Volts Min.
Key On White & Black (1) .1-.5 Volt
(1) Voltage should be higher when blowing air from air cleaner side.