Mass Airflow (MAF) Sensor

Remove rubber cover from electrical connector on airflow sensor. Backprobe between terminals to make voltage measurements. Unplug connector to make resistance measurements. See MAF SENSOR TEST SPECIFICATIONS table. If readings are not as specified, check wiring. See WIRING DIAGRAMS article. If wiring is okay, replace airflow sensor.

MAF SENSOR TEST SPECIFICATIONS

Ign. Switch Wire Colors Readings
Key On Black/Red 10-13 Volts
Key On White 0-0.3 Volts
Key On Black Zero Volts
Engine On Black/Red 13-14 Volts
Engine On White 0.8-1.2 Volts
Engine On Black Zero Volts