FixVault

Removal And Installation

  1. Disconnect battery negative terminal.
  2. Discharge refrigerant using refrigerant recovery system, see DISCHARGE THE SYSTEM .
  3. Disconnect pressure switch harness (A).
  4. Disconnect pipes (B).
  5. Remove mounting bolt (C) and remove receiver drier.
    CAUTION: The receiver drier contains a desiccant. Be sure to put a blind plug in the detached receiver drier to protect it from moisture.
    Fig 1: Removing Receiver Drier
    G02002867
  6. Install the receiver drier in the reverse order of removal.
  7. Charge refrigerant. See EVACUATING AND CHARGING .