Removal And Installation
- Disconnect battery negative terminal.
- Discharge refrigerant using refrigerant recovery system, see DISCHARGE THE SYSTEM .
- Disconnect pressure switch harness (A).
- Disconnect pipes (B).
- Remove mounting bolt (C) and remove receiver drier.CAUTION: The receiver drier contains a desiccant. Be sure to put a blind plug in the detached receiver drier to protect it from moisture.
- Install the receiver drier in the reverse order of removal.
- Charge refrigerant. See EVACUATING AND CHARGING .