FixVault

Fuel Pump: Installation

Install in the reverse order of removal. Do the following:

  1. Always use new gaskets.
  2. Ensure sealing portion is free from fuel or foreign particles before installation.
  3. Tighten nuts in alphabetical sequence shown in Figure to specified torque.
    1. Tightening torque:  4.4 N.m (0.45 kgf-m, 3.3 ft-lb)
    Fig 1: Tightening Nuts Of Fuel Pump Mounting Plate In Alphabetical Sequence
    G02061674
  4. Connect connector to fuel pump relay.
    Fig 2: Connecting Connector To Fuel Pump Relay
    G02061675