Keyless Entry Control Module
MEASURING CONDITION CHART
| Content | Terminal No. | Measuring condition |
|---|---|---|
| Integrated module | 2 (OUTPUT) | Battery voltage is present when pressing the transmitter LOCK/ARM button one time. |
| Power supply (Back-up) | 3 | Battery voltage is constantly present. |
| Door lock switch | 5 (INPUT) | 0 V is present when operating the door lock switch. |
| Trunk room light switch (Sedan), rear gate latch switch (Wagon) | 6 (INPUT) | 0 V is present when opening the trunk lid or rear gate. |
| Ground | 8 | 0 V is constantly present. |
| Integrated module | 9 (OUTPUT) | Battery voltage is present when pressing the transmitter UNLOCK/DISARM button one time. |
| Security control module | 10 | - |
| Security control module | 11 | - |
| Horn relay | 12 (OUTPUT) | 0 V is present when pressing the transmitter UNLOCK/DISARM or LOCK/ARM button. |
| Security control module | 13 | - |
| Ignition switch (ON) | 14 (INPUT) | Battery voltage is present when ignition switch is turned ON. |
| Door unlock switch | 15 (INPUT) | 0 V is present when operating the door lock switch. |
| Key warning switch | 16 (INPUT) | Battery voltage is present when inserting the key into the ignition switch. |