FixVault

RH Side

  1. Before installing front oxygen sensor, apply anti-seize compound only to threaded portion of front oxygen sensor to make the next removal easier.
    CAUTION: Never apply anti-seize compound to protector of front oxygen sensor. 

    Anti-seize compound: 

    SS-30 by JET LUBE 

  2. Install front oxygen sensor.

    Tightening torque: 

    21 N.m (2.1 kgf-m, 15.2 ft-lb) 

    Fig 1: Installing Front Oxygen Sensor
    G00852193Courtesy of SUBARU OF AMERICA, INC.
  3. Install front oxygen sensor harness to bracket.
    Fig 2: Installing Front Oxygen Sensor Harness To Bracket
    G00852194Courtesy of SUBARU OF AMERICA, INC.
  4. Lower the vehicle.
  5. Connect connector to front oxygen sensor.
    Fig 3: Connecting Connector To Front Oxygen Sensor
    G00852195Courtesy of SUBARU OF AMERICA, INC.
  6. Connect battery ground cable.
    Fig 4: Connecting Battery Ground Cable
    G00852196Courtesy of SUBARU OF AMERICA, INC.