FixVault

Without SUBARU Select Monitor

  1. After calling up a DTC, gripped the diagnosis connector terminal 6 from ground terminal.
    Fig 1: Identifying Diagnosis Connector Terminal
    G00959649Courtesy of SUBARU OF AMERICA, INC.
  2. Repeat 3 times within approx. 12 seconds; connecting and disconnecting terminal 6 and ground terminal for at least 0.2 seconds each time.
    Fig 2: Diagnosis Connector Terminal Blinking Pattern (Without Subaru Select Monitor)
    G00959650Courtesy of SUBARU OF AMERICA, INC.
NOTE: After the diagnostics is completed, make sure to clear memory. Make sure only start code (11) is shown after memory is cleared.