Front Oxygen (A/F) Sensor: Installation

  1. Before installing front oxygen (A/F) sensor, apply the anti-seize compound only to the threaded portion of front oxygen (A/F) sensor to make the next removal easier.

    Anti-seize compound: 

    SS-30 by JET LUBE 

    CAUTION: Never apply anti-seize compound to protector of front oxygen (A/F) sensor.
    Fig 1: Installing Oxygen (A/F) Sensor
    G00800607Courtesy of SUBARU OF AMERICA, INC.
  2. Install the front oxygen (A/F) sensor.

    Tightening torque: 

    21 N.m (2.1 kgf-m, 15.2 ft-lb) 

    Fig 2: Installing Front Oxygen (A/F) Sensor
    G00800608Courtesy of SUBARU OF AMERICA, INC.
  3. Lower the vehicle.
  4. Connect the connector to front oxygen (A/F) sensor, and then connect the connector to engine hanger.
    Fig 3: Connecting Connector To Front Oxygen (A/F) Sensor
    G00800609Courtesy of SUBARU OF AMERICA, INC.
  5. Connect the battery ground cable to battery.
    Fig 4: Connecting Battery Ground Cable To Battery
    G00800610Courtesy of SUBARU OF AMERICA, INC.