Starting/Charging Systems (H4SO): General Description: Specifications
STARTING GENERAL DESCRIPTION
| Item | Designation | |||
|---|---|---|---|---|
| MT | AT | |||
| Starter | Type | Reduction type | ||
| Model | 228000-7131 | 228000-7141 | ||
| Manufacturer | DENSO CORPORATION | |||
| Voltage and output | 12 V - 1.0 kW | 12 V - 1.4 kW | ||
| Direction of rotation | Counterclockwise (when observed from pinion) | |||
| Number of pinion teeth | 9 | |||
| No-load characteristics | Voltage | 11 V | ||
| Current | 90 A or less | |||
| Rotating speed | 3,000 rpm or more | 2,900 rpm or more | ||
| Load characteristics | Voltage | 8 V | ||
| Current | 280 A or less | 370 A or less | ||
| Torque | 9.8 N.m (1.0 kgf-m, 7.2 ft-lb) | 13.7 N.m (1.4 kgf-m, 10.1 ft-lb) | ||
| Rotating speed | 900 rpm or more | 880 rpm or more | ||
| Lock characteristics | Voltage | 5 V | ||
| Current | 800 A or less | 1,050 A or less | ||
| Torque | 27.5 N.m (2.8 kgf-m, 20.3 ft-lb) or more | |||
| Generator | Type | Rotating-field three-phase type, Voltage regulator built-in type | ||
| Model | A2TB2891ZC | |||
| Manufacturer | MITSUBISHI ELECTRIC |
|||
| Voltage and output | 12 V - 90 A | |||
| Polarity on ground side | Negative | |||
| Rotating direction | Clockwise (when observed from pulley side.) | |||
| Armature connection | 3-phase Y-type | |||
| Output current | 1,500 rpm - 36 A or more 2,500 rpm - 65A or more 5,000 rpm - 86 A or more |
|||
| Regulated voltage | 14.1 - 14.8 V [20°C (68°F)] | |||
| Battery | Reserve capacity | min. | 90 | 110 |
| Cold cranking ampere | A | 430 | 490 | |