Electrical Specification

Fig 1: Electrical Specification
G03809379Courtesy of SUBARU OF AMERICA, INC.
ELECTRICAL SPECIFICATION

Content Terminal No. Measuring condition
Empty 1 -
Ignition switch (ON) 2 (INPUT) Battery voltage is present when ignition switch is turned to ON.
Passive arm 3 -
Rear gate latch switch 4 (INPUT) 0 V is present when rear gate is open.
Door switch 5 (INPUT) 0 V is present when any door is open.
Empty 6 -
Keyless entry control unit 7 -
Keyless entry control unit 8 -
Security indicator light 9 (OUTPUT) 0 V is present when the alarm operation is activated.
Keyless entry control unit 10 -
Power supply (Back-up) 13 Battery voltage is constantly present.
Ground 14 0 V is constantly present.
Interrupt relay 15 (OUTPUT) Battery voltage is present when the alarm operation is activated.
Security horn relay 16 (INPUT) Battery voltage is present when the alarm operation is activated.
Security horn 17 (OUTPUT) Battery voltage is present when the alarm operation is activated.
Security horn relay 18 (INPUT) Battery voltage is present when the alarm operation is activated.