FixVault

Trunk Lid Lock Assembly: Inspection

  1. Disconnect the trunk lid actuator harness connector.
  2. Connect the battery to trunk lid actuator terminals.
    Fig 1: Connecting Battery To Trunk Lid Actuator Terminals
    G03833896Courtesy of SUBARU OF AMERICA, INC.
    ACTUATOR OPERATION SPECIFICATION

    Terminal No. Actuator operation
    No. 2 (+) and No. 1 (-) Locked -> Unlocked

    If defective, replace the trunk lid actuator.

  3. Check the striker for deformation or abnormal wear.
  4. Check the safety lever for improper movement.
  5. Check other levers and the spring for rust formation and unsmooth movement.
  6. Check the cable of trunk opener for smooth operation.