FixVault

Mode $06

Refer to test value of troubleshooting and data of test limit on support data bit sequence table. List of support data is shown in TID VALUE CHART  .

TID VALUE CHART

TID CID Test value
$81 $01 Catalyst system efficiency
$83 $01 Evaporative emission control system 0.04 inch leak
$02
$03
$04
$05 Evaporative emission control system 0.02 inch leak
$86
$84 $01 A/F sensor circuit slow response (Bank 1 Sensor 1)
$85 $01 O2 sensor circuit slow response (Bank 1 Sensor 2)(rich --> lean)
$02 O2 sensor circuit slow response (Bank 1 Sensor 2)(lean --> rich)
$87 $01 A/F sensor circuit slow response (Bank 2 Sensor 1)
$88 $01 O2 sensor circuit slow response (Bank 2 Sensor 2)(rich --> lean)
$02 O2 sensor circuit slow response (Bank 2 Sensor 2)(lean -> rich)
$41 $81 O2 sensor circuit (Bank 1 Sensor 2)
$02