Read Current Data
- On the «Main Menu» display screen, select the {Each System Check} and press the [YES] key.
- On the «System Selection Menu» display screen, select the {Brake Negative Pressure Pump System} and press the [YES] key.
- Press the [YES] key after the {3.0 DOHC} is displayed.
- On the «Negative Pressure Diagnosis Menu» display screen, select the {Current Data Display/Save}, and then press the [YES] key.
- On the «Data Display Menu» screen, select the {Data Display} and press the [YES] key.
- Using a scroll key, scroll the display screen up or down until necessary data is shown.
- A list of the support data is shown in the following table.
LIST OF SUPPORT DATA
| Display | Contents to be monitored | Unit of measure |
|---|---|---|
| Atmospheric pressure | Atmospheric pressure is displayed. | mm Hg, kPa or psig |
| Brake booster pressure | Brake booster pressure is displayed. | mm Hg, kPa or psig |
| Test mode terminal | Test mode terminal connection status is displayed. | D Check or U Check |
| Negative pressure pump motor | Negative pressure motor operating status is displayed. | ON or OFF |
| Negative pressure pump motor relay | Negative pressure pump motor relay operating status is displayed. | ON or OFF |
NOTE:
For details concerning operation procedure, refer to the "SUBARU SELECT MONITOR OPERATION MANUAL ".