Section 12 (Starting/Charging Systems (H4SO)): Generator: Inspection: Stator
WARNING: This page is about a different variant/trim than selected.
- Continuity test
Inspect the stator coil for continuity between each end of the lead wires. If resistance is 1 M Ω or more, the lead wire is broken, and so replace the stator assembly.
- Insulation test
Inspect the stator coil for continuity between stator core and each end of lead wire. If resistance is 1 Ω or less, the stator coil is grounded, and so replace the stator assembly.