FixVault

Abs Sequence Control With SUBARU Select Monitor

  1. Connect the Subaru Select Monitor to the Subaru data link connector under the driver's side instrument panel lower cover.
  2. Turn the ignition switch ON.
  3. Set the Subaru Select Monitor switch to ON.
  4. Set the Subaru Select Monitor to "BRAKE CONTROL" mode.
  5. When the "Function check sequence" is selected, the "ABS sequence control" will start.
  6. Execute the following steps when the message "Press Brake Pedal with braking force of 100 to 150 kgf" is displayed.
    1. When using a brake tester, press the brake pedal with a force of 1,000 N (102 kgf, 224 lb).
    2. When using the pressure gauge, press the brake pedal so as to make the pressure gauge indicate 3,500 kPa (36 kg/cm2 , 508 psi).
  7. If "Press YES" is displayed, press the «YES» key.
  8. The brake line being operated is displayed on the Subaru Select Monitor.