FixVault

Starting/Charging (H4SO): Generator: Removal

  1. Disconnect the ground cable from battery.
    Fig 1: Disconnecting Battery Ground Cable
    G04988132
  2. Remove the collector cover. (Turbo model)
  3. Disconnect the connector and terminal from generator.
    • Non-turbo model
      Fig 2: Identifying Generator Connector - Non-Turbo Model
      G04997958
    • Turbo model
    Fig 3: Identifying Generator Connector - Turbo Model
    G04992963
  4. Remove the front side V-belts.

    <Ref. to FRONT SIDE BELT Removal, V-belt. >

  5. Remove the bolts which install the bracket to remove the generator.
Fig 4: Locating Generator Bracket Bolts
G04997960