FixVault

Diagnostic Method

Judge as NG when the continuous time of completing the malfunction criteria below becomes more than predetermined amount of time (2.5 seconds).

Judge as OK and clear the NG when the following conditions are not met.

Judgment Value 

JUDGMENT VALUE

Malfunction Criteria Threshold Value
MIL lighting request from TCM set

Time Needed for Diagnosis:  2.5 seconds

Malfunction Indicator Light Illumination:  Illuminates as soon as a malfunction occurs.