Diagnostic Method

Abnormality Judgment 

Judge as NG when the continuous time of completing the malfunction criteria below becomes 0.3 seconds or more.

Judgment Value 

JUDGMENT VALUE

Malfunction Criteria Threshold Value
| Atmospheric pressure - Manifold pressure | ≥ 26.7 kPa (200 mmHg, 7.88 inHg)
| Intake manifold pressure at engine startup - Manifold pressure | <1.33 kPa(10 mmHg, 2.95 inHg)

Time Needed for Diagnosis:  0.3 seconds

Malfunction Indicator Light Illumination:  Illuminates when malfunction occurs in 2 continuous driving cycles.

Normality Judgment 

Judge as OK and clear the NG when the continuous time with the following criteria established is more than 0.3 seconds.

Judgment Value 

JUDGMENT VALUE

Malfunction Criteria Threshold Value
Atmospheric pressure - Manifold pressure < 26.7 kPa (200 mmHg, 7.88 inHg)