Diagnostic Method
Abnormality Judgment
Judge as NG when the continuous time of completing the malfunction criteria below becomes 0.3 seconds or more.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| | Atmospheric pressure - Manifold pressure | | ≥ 26.7 kPa (200 mmHg, 7.88 inHg) |
| | Intake manifold pressure at engine startup - Manifold pressure | | <1.33 kPa(10 mmHg, 2.95 inHg) |
Time Needed for Diagnosis: 0.3 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
Judge as OK and clear the NG when the continuous time with the following criteria established is more than 0.3 seconds.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Atmospheric pressure - Manifold pressure | < 26.7 kPa (200 mmHg, 7.88 inHg) |