Mode $06
Refer to the test value of troubleshooting and data of test specification on the support data bit sequence table. A list of the support data is shown in the following table.
SUPPORT DATA
| TID | CID | Test value & Test specification |
|---|---|---|
| $41 | $81 | O2 Sensor Circuit (Bank 1 Sensor 2) |
| $02 | ||
| $81 | $01 | Catalyst system efficiency |
| $83 | $01 | Evaporative Emission Control System (0.04 inch leak) |
| $02 | Evaporative Emission Control System (0.04 inch leak) | |
| $03 | Evaporative Emission Control System (0.04 inch leak) | |
| $04 | Evaporative Emission Control System (0.04 inch leak) | |
| $05 | Evaporative Emission Control System (0.02 inch leak) | |
| $86 | Evaporative Emission Control System (0.02 inch leak) | |
| $84 | $01 | A/F Sensor Circuit Slow Response (Bank 1 Sensor 1) |
| $85 | $01 | O2 Sensor Circuit Slow Response (Bank 1 Sensor 2) Rich → Lean |
| $02 | O2 Sensor Circuit Slow Response (Bank 1 Sensor 2) Lean → Rich | |
| $89 | $81 | Secondary air system |
| $82 | ||
| $83 | ||
| $04 | ||
| $05 |