Check Body Integrated Unit Power Supply And Ground Circuit
BODY INTEGRATED UNIT POWER SUPPLY AND GROUND CIRCUIT CHECKING PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK POWER SUPPLY OF BODY INTEGRATED UNIT.
|
Is the voltage more than 10 V? | Go to step 2. | Check the harness for open or short between body integrated unit and fuse. |
2 CHECK BODY INTEGRATED UNIT GROUND CIRCUIT.
|
Is the resistance less than 10 Ω? | Check the body integrated unit. < Ref. to BASIC DIAGNOSTIC PROCEDURE . > | Repair the harness. |