FixVault

Switch Assembly Operation

NOTE: Test period of each test must be within short time (3 - 5 seconds).
  1. Vacuum test

    Disconnect the harness from terminal M and connect it as shown in the figure. Make sure the pinion gear sticks out.

    Fig 1: Checking Vacuum Test
    G05017441
  2. Hold test

    Make sure the pinion gear remains stick out even after disconnecting terminal M in the above condition.

    Fig 2: Checking Hold Test
    G05017442
  3. Return test

    Connect the positive terminal to terminal S and the negative terminal to terminal M and starter body to pull the pinion gear at the main contact point. Make sure the pinion gear returns to its original position when the terminal S is disconnected.

    Fig 3: Checking Return Test
    G05017443