FixVault

Wastegate Control Solenoid Valve: Removal

  1. Remove the collector cover.
  2. Disconnect the ground cable from battery.
    Fig 1: Removing Collector Cover
    G05019586
  3. Disconnect the connector from the wastegate control solenoid valve (A).
  4. Disconnect pressure hose (B) from the waste-gate control solenoid valve.
  5. Remove the wastegate control solenoid valve from the bracket
    Fig 2: Identifying Wastegate Control Solenoid Valve And Pressure Hose With Bolt
    G05017826