Check Door Switch
DIAGNOSTIC PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK DOOR SWITCH CIRCUIT. Measure the voltage between the keyless entry control module harness connector terminal and the body ground. Connector & terminal Front and rear door: (B176) No. 6 (+) - Chassis ground (-): Rear gate: (B176) No. 7 (+) - Chassis ground (-): |
Is the voltage 0 V when each door or rear gate is opened? | Go to step 2. | Go to step 3. |
| 2 CHECK DOOR SWITCH CIRCUIT. Measure the voltage between the keyless entry control module harness connector terminal and the body ground. Connector & terminal Front and rear door: (B176) No. 6 (+) - Chassis ground (-): Rear gate: (B176) No. 7 (+) - Chassis ground (-): |
Is the voltage more than 10 V when each door or rear gate is closed? | The door switch is OK | Go to step 3. |
3 CHECK DOOR SWITCH.
|
Is the resistance more than 1 MΩ when door switch is pushed? | Go to step 4. | Replace the door switch. |
| 4 CHECK DOOR SWITCH. Measure the resistance between door switch terminals. Terminals Door switch No. 1 - No. 3: Rear gate latch switch No. 1 - No. 2: |
Is the resistance less than 1 Ω when door switch is released? | Check the harness for open circuits or shorts between the keyless entry control module and the door switch. | Replace the door switch. |
DIAGNOSTIC PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK SECURITY INDICATOR LIGHT.
|
Does the security indicator light illuminate? | Replace the keyless entry control module. | Go to step 2. |
2 CHECK POWER SUPPLY FOR SECURITY INDICATOR LIGHT.
|
Is the voltage more than 10 V? | Go to step 3. | Check the harness for open or short circuits between combination meter and fuse. |
| 3 CHECK SECURITY INDICATOR LIGHT CIRCUIT. Measure the resistance between the combination meter harness connector terminal and keyless entry control module harness connector terminal. Connector & terminal (i12) No. 4 - (B176) No. 15: |
Is the resistance less than 10 Ω? | Replace the combination meter. | Check the harness for open or short circuits between combination meter and keyless entry control module. |