Check Interrupt Relay Circuit
DIAGNOSTIC PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK INTERRUPT RELAY. Remove and check interrupt relay. <Ref. to INTERRUPT RELAY . > |
Is the interrupt relay normal? | Go to step 2. | Replace the interrupt relay. |
| 2 CHECK INTERRUPT RELAY POWER SUPPLY. Measure the voltage between interrupt relay harness connector terminal and chassis ground. Connector & terminal (B59) No. 1 (+) - Chassis ground (-): |
Is the voltage more than 10 V when ignition switch is turned to START? | Go to step 3. | Check the harness for open circuits or shorts between the interrupt relay and the ignition switch. |
3 CHECK THE HARNESS BETWEEN INTERRUPT RELAY AND KEYLESS ENTRY CONTROL MODULE.
|
Is the resistance less than 10 Ω? | Replace the keyless entry control module. | Check the harness for open or short circuits between interrupt relay and keyless entry control module. |