FixVault

Abs Sequence Control With SUBARU Select Monitor

NOTE: In the event of any trouble, sequence control will not operate. In this case, diagnose the failure. <Ref. to PROCEDURE , Basic Diagnostic Procedure .>
  1. Connect the Subaru Select Monitor to data link connector under the driver's side instrument panel lower cover.
  2. Turn the ignition switch to ON.
  3. Run the Subaru Select Monitor.
  4. Set the Subaru Select Monitor to {Brake Control} mode.
  5. When the {Function check sequence} is selected, the ABS sequence control will start.
  6. Execute the following operations when the message {Press the brake pedal so that the brake pedal force is between 100 and 150 kgf) is displayed.
    1. When using a brake tester, press the brake pedal pad with a force of 981 N (100 kgf, 221 lbf).
    2. When using a pressure gauge, press the brake pedal so that the pressure gauge indicates 3,432 kPa (35 kgf/cm2 , 498 psi).
  7. {Press the "YES" key} will be displayed. Press the [YES] key.
  8. The brake system being operated is displayed on the Subaru Select Monitor.