COOLING SYSTEM SPECIFICATION

Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity (US qt, lmp qt) Approx. 7.2 (7.6, 6.3)
Water pump Type Centrifugal impeller type
Discharge performance I Discharge rate (US gal, lmp gal)/min 320 (84.5, 70.4)
Pump speed - Discharge pressure 5,500 rpm - 176.5 kPa (18 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 73.2 (2.88)
Number of impeller vanes 6
Number of pump sprocket teeth 22
Thermostat Type Wax pellet type
Starting temperature to open 80 - 84°C (176 - 183°F)
Fully opens 95°C (203°F)
Valve lift mm (in) 9.0 (0.354) or more
Valve bore mm (in) 35 (1.38)
Radiator fan Motor input Main fan W 160
Sub fan W 160
Fan diameter/Blade Main fan 320 mm (12.6 in)/5
Sub fan 320 mm(12.6 in)/7
Radiator Type Down flow, pressure type
Core dimensions Width x Height x Thickness mm (in) 690 x 349 x 16 (27.17 x 13.74 x 0.63)
Pressure range in which cap valve is open kPa (kgf/cm2 , psi) Above: 108 ± 14.7 (1.1 ± 0.15, 16 ± 2) Below: The atmospheric pressure or less
Fins Corrugated fin type
Reservoir tank Capacity (US qt, lmp qt) 0.45 (0.48, 0.40)
COOLANT CAPACITY SPECIFICATION

Coolant Recommended materials Item number Alternative
Coolant SUBARU coolant 000016218 Phosphoric acid (non-amine) type
Water for dilution Distilled water - Soft water or tap water
Cooling system protective agent Cooling system conditioner SOA345001 None
A/C COMPRESSOR SPECIFICATION

A/C compressor A/C middle pressure switch Engine coolant temperature
Increase: less than 95°C (203°F) Decrease: less than 93°C (199°F) Increase: 95 - 101°C (203 - 214°F) Decrease: 93 - 99°C (199 - 210°F) Increase: 102°C (216°F) or more Decrease: 100°C (212°F) or more
OFF 0% Refer to Fig 1 100%
ON OFF Refer to Fig 1 100%
ON Refer to Fig 1 100%
Fig 1: Fan Speed And Water Temperature Graph
G05341423Courtesy of SUBARU OF AMERICA, INC.