FixVault

VDC Hydraulic Control Module (VDCH/M): Installation: VDCH/M

  1. Install the VDCH/M.
    Fig 1: Locating VDCH/M Bolts
    G04994859

    Tightening torque: 

    18 N.m (1.8 kgf-m, 13.3 ft-lb) 

  2. Secure the grounding wire of the VDCH/M and apply the specified grease to the ground terminals.

    Specified grease: 

    Nippeco LT or GB 

    Tightening torque: 

    33 N.m (3.4 kgf-m, 24.3 ft-lb) 

  3. Connect brake pipes to the VDCH/M connectors.

    Tightening torque: 

    15 N.m (1.5 kgf-m, 11.1 ft-lb) 

  4. Fasten the VDCH/M connector to the connector bracket.
    CAUTION: Match the connector to the corresponding socket.
  5. Connect the connector to VDCH/M.
    Fig 2: Identifying VDCH/M Connector And Relay Box Connector
    G05658041
  6. Install the air intake duct.
  7. Connect the battery ground cable to the battery.
  8. Bleed air from the brake system.